MPO/MTP Fiber Patch Cord Manufacturer in China
Get Factory Price Start From 50PC
As an expert manufacturer, HOLIGHT offering high quality Custom MPO/MTP Fiber Optic Patch Cord solutions to enhance your yield.
We specialize in manufacturing a wide array of MPO/MTP fiber optic patch cords, including MPO/MTP Fiber Optic Patch Cord, MPO/MTP Ribbon Patch Cord, MPO/MTP Breakout Patch Cord, MPO/MTP Loopback, and Waterproof MPO/MTP Patch Cord. Our expertise lies in crafting these diverse and specialized patch cords to meet varied networking needs. Whether it’s high-density connections, specialized configurations, or waterproof requirements, we have the capabilities to deliver top-quality solutions. Explore our range to find precisely tailored MPO/MTP patch cords designed for optimal performance and reliability in your network infrastructure.
12Fibers 24Fibers MPO OM4 Fiber Patch Cord
Mini Plus MPO OM3 Fiber Patch Cord
24F MTP-24 to 2 x MTP-12 SM Fiber Patch Cord
MPO/MTP-LC SM 8F Ribbon Fiber Patch Cord
24Fiber OM3 MTP/MPO Fiber Optic Trunk Cable
MPO to LC OM4 8Fibers Breakout patch cable
ODVA MPO/MTP Waterproof Patch Cord
MPO/MTP to SCA 12Fibers Breakout Fiber Optic Cord
MPO Female 12C Ribbon Fiber Patch Cord
24Fibers MPO-8fibers 3xMPO OM4 Mini 3.0mm Fiber Patch Cable
24Fibers DVA MPO-ODVA MPO φ7.0mm Waterproof Fiber Patch Cord
Mini Plus MPO to Mini Plus MPO 3.0mm OFNP Fiber Patch Cord
24 Core Fully Loaded MPO/MTP Cassette for Fiber Optic Patch Panel
Plug and Play Ultra-thin MPO/MTP Cassette 12 Fibers
12 or 24Fibers MPO MTP to LC Cassette
The Ultimate Guide to MPO/MTP Patch Cables
MPO (Multi-fiber Push-On) and MTP (Multi-fiber Termination Push-On) patch cables are fiber optic connectors designed for transmitting large volumes of data swiftly and efficiently. These high-density connectors contain multiple fibers within a single connector, enabling the simultaneous transfer of data across multiple channels. MPO/MTP cables are renowned for their versatility and are commonly used in various applications, including data center interconnections, high-speed networks, and telecommunications infrastructure.
1. What are MPO/MTP Connectors?
MPO/MTP connectors are specialized fiber optic connectors designed to simplify and optimize high-density fiber optic connections. They are often used in data centers, telecommunications networks, and other high-bandwidth applications. MPO/MTP connectors are unique in that they can house multiple optical fibers within a single compact connector.
MPO/MTP-8 | Contains 8 fibers in a single-row configuration. Often used for 10G and 25G Ethernet connections. |
MPO/MTP-12 | Contains 12 fibers in a single-row configuration. Suitable for 40G and 100G Ethernet connections. |
MPO/MTP-24 | Contains 24 fibers in a single-row configuration. Commonly used in high-density data center environments |
MPO/MTP-48 | Contains 48 fibers, usually in a double-row configuration. Used for very high-density applications and to support emerging high-speed technologies |
2. Available Cable Types for MPO/MTP Patch Cables
Different MPO/MTP cable types are available to suit various deployment scenarios:
(1) Trunk Cable: Trunk cables are robust and typically have MPO/MTP connectors on both ends. They serve as the primary backbone cables in data centers, connecting MPO/MTP modules and cassettes. Trunk cables are designed for high-density, high-speed connections over short to moderate distances within the data center.
(2) MPO/MTP Ribbon Cable: MPO/MTP ribbon cables consist of multiple individual fibers organized in ribbon form, typically 8 to 24 fibers per ribbon. They are used for high-density applications, and the ribbon design makes them easier to manage and install. MPO/MTP ribbon cables are often employed in parallel optics, such as 40 Gbps and 100 Gbps connections.
(3)MPO/MTP Breakout Cable: MPO/MTP breakout cables, also known as fan-out cables, are used to transition from a single MPO/MTP connector to multiple individual connectors, such as LC, SC, or ST connectors. They are used to connect MPO/MTP trunk cables to various networking equipment, allowing for flexibility in connecting different types of equipment within a data center or network.
(4)MPO/MTP-LC Harness Cable: MPO/MTP-LC harness cables are designed to connect MPO/MTP connectors on one end to LC connectors on the other end. These cables are used to interface between MPO/MTP backbone cabling and equipment with LC interfaces, such as switches and routers.
(5)MPO/MTP Conversion Cable: MPO/MTP conversion cables are used when you need to connect different types of MPO/MTP connectors, such as MPO to MTP or vice versa, or when adapting between different MPO/MTP gender types (male to female or female to male).
3. What is the Difference Between Single-mode and Multimode MPO/MTP Cables?
The main difference between single-mode and multimode MPO/MTP cables lies in the type of optical fiber they use, which impacts their performance and application suitability:
(1) Single-Mode MPO/MTP Cables:
Fiber Type: Single-mode MPO/MTP cables use single-mode optical fibers (SMF) with a small core size (typically around 9 microns). These fibers allow only one mode of light to propagate, which means that light travels in a straight path with minimal dispersion.
Applications: Single-mode MPO/MTP cables are primarily designed for long-distance, high-bandwidth applications. They are commonly used in scenarios where data transmission needs to cover extensive distances, such as long-haul telecommunications networks, metropolitan area networks (MANs), and high-speed, long-distance data connections.
Advantages: Single-mode fibers offer lower signal attenuation, allowing data to travel over much greater distances without significant loss. They are well-suited for high-speed and long-range data transmission.
(2) Multimode MPO/MTP Cables:
Fiber Type: Multimode MPO/MTP cables use multimode optical fibers (MMF) with a larger core size (typically either 50 or 62.5 microns). These fibers allow multiple modes of light to propagate simultaneously, which results in dispersion (signal spreading) over short distances.
Applications: Multimode MPO/MTP cables are typically used for shorter-distance connections within data centers, local area networks (LANs), and other high-speed, short-distance applications. They are ideal for scenarios where high bandwidth is required over shorter spans.
Advantages: Multimode fibers are cost-effective and support high-speed data transmission over moderate distances. They are commonly used for connections between servers, switches, and other networking equipment in data center environments.
4. Difference Between MPO Male and MPO Female
MPO connectors are used in fiber optic communications for high-density connections. “MPO Male” and “MPO Female” refer to two different types of MPO connectors based on their gender or connector design. Here are the main differences between the two:
(1) MPO Male Connector:
- MPO male connectors typically have multiple pins or fibers arranged in a rectangular or square pattern on the front face of the connector.
- They often feature guide pins or alignment pins on the connector body, which help ensure precise alignment when connecting to a female MPO connector.
- MPO male connectors are designed to be plugged into MPO female connectors, which have corresponding holes or sockets for the pins on the male connector to fit into.
- These connectors are commonly found on the ends of patch cords or trunk cables used to connect active equipment like switches, routers, or transceivers in a fiber optic network.
(2) MPO Female Connector:
- MPO female connectors have corresponding holes or sockets for the pins on MPO male connectors to fit into.
- Unlike MPO male connectors, they typically do not have guide pins or alignment pins, as their design is intended to receive and align with the pins on the male connector.
- MPO female connectors are commonly used in passive components like patch panels, cassettes, and fiber distribution units (FDUs) within data centers and high-density fiber optic networks.
- These connectors provide the receptacle for MPO male connectors to connect to and are often used for cross-connecting or distributing optical signals within the network.
In summary, the main difference between MPO Male and MPO Female connectors is their design and purpose. MPO male connectors have pins and are used for making connections to active equipment, while MPO female connectors have sockets and are typically used in passive components for cross-connections and distribution. Both types of connectors play a crucial role in high-density fiber optic installations.
5. What are the Polarities of MPO/MTP?
MPO/MTP connectors are used in fiber optic networks to connect multiple optical fibers simultaneously. The polarity of MPO/MTP connectors is an important consideration when setting up these connections to ensure proper signal transmission. Polarity defines how optical signals are transmitted from one end of a fiber link to the other. There are three main polarity methods for MPO/MTP connectors:
(1) Method A (Straight-Through):
In Method A, all fibers are in a straight-through configuration, meaning that fiber 1 on one connector is connected to fiber 1 on the other, fiber 2 to fiber 2, and so on.
This method is often used for parallel optics applications where the transmitter on one end aligns with the receiver on the other end without any crossover. Method A is commonly used in applications like 40GBASE-SR4 and 100GBASE-SR10.
(2) Method B (Reversed):
In Method B, fibers are crossed over between connectors, meaning that fiber 1 on one connector is connected to fiber 12 on the other, fiber 2 to fiber 11, and so on.
This method is used when there’s a need to flip the transmit and receive paths between connectors, which is typical in some bidirectional transceiver applications. Method B is often used in 100GBASE-LR4 and 100GBASE-ER4 applications.
(3) Method C (Cross Pair):
In Method C, which can flip the pairs in the cable, so that position 1 reaches position 2, position 2 reaches position 1, and 3 to 4,4 to 3,5 to 6, 6 to 5, etc. Although this works well for duplex applications where A-B type jumpers are used at both ends, it is still not recommended because you may, need to migrate from duplex to Parallel one day.
Choosing the right polarity method depends on the specific requirements of your fiber optic network, the type of transceivers and equipment you are using, and the desired signal flow. It’s important to carefully plan and document the polarity to ensure proper connectivity and signal transmission in your MPO/MTP-based fiber optic infrastructure. Incorrect polarity can lead to signal loss and network issues.
6. Rules for Establishing MTP/MPO Polarity Connections
When the fiber patch cord has different polarity schemes, IT personnel must be conscientious when replacing it on-site. Those who need to learn the polarity or are eager to start and run the equipment may misuse jumpers, affecting optical signal transmission.
(1) The Rule for MTP/MPO Cable and Patch Cord Connection
In the case of A-to-A jumper and A-to-B jumper, there are three general types of arrays(multi-core) optical cable components. Note that the alignment pins on the MTP/MPO connectors are essential for maintaining the correct polarity. Therefore, before using jumpers to connect MTP/MPO fibers, it is necessary to ensure the correct pin positions.
A to B type LC/SC duplex patch cord is a standard crossover that maps the Tx port to the Rx port. By flipping, the polarity of the A to B type jumper is correct. MTP backbone cable type B reverses the fiber position at each end(1 pair 12 and 12 pair 1), and the connector keys are facing up. It is recommended to use this cable connection to maintain the correct MTP/MPO polarity.
(2) Rules for MTP/MPO Cable and Cassette Connection
The selection of the MTP/MPO distribution box also determines the selection of the MTP/MPO cable. You’d better choose an optical fiber distribution box with suitable locating pins so that the MTP/MPO distribution box can perfectly match the MTP/MPO connector at both ends of the MTP/MPO optical fiber cable.
In addition, the back of the adapter installed on the distribution box is defined as Method A or Method B to comply with TIA standards.
7. Why are Polarity and Gender Important in MPO/MTP Connectors and Cables?
Polarity and gender are critical aspects of MPO/MTP connectors and cables in fiber optic networks because they ensure that optical signals are transmitted accurately and efficiently. Let’s explore why polarity and gender are important:
(1) Signal Integrity: In fiber optic communication, maintaining the correct signal path is crucial to ensure that data is transmitted accurately and without errors. Proper polarity ensures that the transmit (TX) and receive (RX) signals are correctly aligned between interconnected devices. Incorrect polarity can lead to signal loss, high bit error rates, and network instability.
(2) Compatibility: MPO/MTP connectors are used in various network configurations, including point-to-point connections, multi-path connections, and network topologies with various transceiver types. Ensuring that connectors have compatible gender and polarity is essential to making these diverse connections work seamlessly.
(3) Plug-and-Play Convenience: MPO/MTP connectors are often used in high-density environments like data centers, where quick and efficient connections are essential. Having standardized polarity and gender ensures that cables and connectors can be plugged in without the need for complex and error-prone adjustments.
(4) Minimizing Insertion Loss and Return Loss: Proper polarity and gender alignment help minimize insertion loss (signal attenuation as it passes through the connector) and return loss (the reflection of signals back into the transmitter). These losses can significantly impact signal quality and network performance.
(5) Avoiding Damage and Misalignment: MPO/MTP connectors can be damaged if connectors with incompatible genders are forcibly mated. Ensuring that connectors have the correct gender prevents damage and misalignment, extending the lifespan of the connectors and reducing maintenance costs.
(6) Compliance with Industry Standards: Adhering to industry standards for MPO/MTP polarity and gender, such as those outlined in TIA-568 or IEC 61755-3-31, ensures that your network components are compatible with those of other manufacturers. This standardization promotes interoperability and simplifies network design and troubleshooting.
(7) Network Reliability: Correct polarity and gender configurations contribute to the overall reliability of fiber optic networks. Inconsistent or mismatched connectors can lead to intermittent connectivity issues and downtime.
In summary, polarity and gender are essential aspects of MPO/MTP connectors and cables because they play a fundamental role in maintaining signal integrity, compatibility, and reliability in fiber optic networks. Properly aligned connectors ensure that optical signals traverse the network accurately and efficiently, which is crucial for high-performance data transmission and the overall functionality of modern data centers and telecommunications networks.
8. How to Clean and Maintain MPO/MTP Connectors?
Cleaning and maintaining MPO/MTP connectors is essential to ensure the proper functioning and reliability of your fiber optic network. Dirty or contaminated connectors can lead to signal loss and network issues.
Here are the Steps to Clean and Maintain MPO/MTP Connectors:
(1) Materials Needed: MPO/MTP cleaning kits, which typically include cleaning sticks, lint-free wipes, and cleaning fluid specifically designed for fiber optics.
(2) Inspect the Connectors: Before cleaning, visually inspect the MPO/MTP connectors to check for any visible dirt, dust, or contaminants.
(3) Wash Your Hands: Ensure that your hands are clean and free from oils and debris before handling connectors.
(4) Prepare the Cleaning Tools: If you are using a cleaning kit, follow the instructions provided to prepare the cleaning tools.
(5) Dust Removal: Gently blow any loose dust or particles away from the connectors.
(6) Cleaning Stick or Cassette: If using a cleaning stick or cassette, insert it into the MPO/MTP connector. Make sure it is properly aligned with the fibers.
(7) Push-Pull Cleaning Method: For MPO/MTP connectors, use the “push-pull” method. Push the cleaning tool firmly into the connector until it clicks into place, and then pull it back out.
(8) Repeat as Needed: Depending on the cleanliness of the connector, you may need to repeat the cleaning process several times. Always follow the manufacturer’s recommendations for the number of cleaning cycles.
(9) Visual Inspection: After cleaning, visually inspect the connector again to ensure it is clean and free from contaminants.
(10) Reconnect Carefully: When plugging MPO/MTP connectors into ports or adapters, do so carefully to avoid introducing contaminants. Make sure the connectors are properly aligned and engage smoothly.
Maintenance Tips:
(1) Keep dust caps on unused connectors to prevent contamination.
(2) Store connectors in a clean, dust-free environment when not in use.
(3) Periodically inspect and clean connectors as part of routine maintenance.
(4) Avoid touching the end faces of connectors with your fingers, as oils from your skin can transfer onto them.
(5) Use proper cleaning tools and materials designed for fiber optics.
(6) Follow the manufacturer’s guidelines for cleaning and maintenance.
Regular cleaning and maintenance of MPO/MTP connectors will help ensure the continued reliability and performance of your fiber optic network. Contaminant-free connectors are essential for maintaining low insertion loss and signal integrity.
9. What are MPO/MTP Fiber Trunk Cables?
MPO/MTP fiber trunk cables are pre-assembled cables utilizing a multi-fiber ribbon cable equipped with an MPO/MTP fiber connector. “MPO” stands for “Multi-Fiber-Push-On,” denoting a common fiber connector accepting 12 or 24 fiber strands. This connector type operates by pushing on similarly to the legacy SC-style fiber connector. Generally, MPO connectors find application in high-speed fiber backbone connectivity or scenarios requiring rapid multiple fiber connections.
Differentiating between MPO and MTP can be confusing. “MTP” stands for “Multi-Fiber Termination Push-On,” a trademark of “US Conec.” It is an enhanced version of the MPO connector, featuring several engineered improvements enhancing both optical and mechanical performance compared to a generic MPO connector.
It’s important to note that while both MPO/MTP connectors are available in 12- and 24-fiber strand connectivity, they are not interchangeable. Attempting to connect an MPO/MTP 12-strand connector to an MPO/MTP 24-strand connector will not align the rows of fiber strands correctly.
10. How to Choose the Best MTP Fiber Optic Patch Cable
The MTP (Multifiber Termination Push-on) fiber optic patch cable is a crucial component in modern networking systems. It employs MTP connectors, an evolved version of the MPO (Multifiber Push-On) connectors, renowned for improved mechanical strength and enhanced performance.
Connector Types: Choose from a variety of connector types including ST, SC, LC, FC, MTP, MPO, etc.
Fiber Modes: Consider the Single Mode and various Multimode options available for different transmission needs.
Cable Construction: Select between Simplex, Duplex, and Multi-Fiber cables, considering different fiber counts and configurations.
Cable Specifications: Look into factors like cable diameter, jacket materials, colors, and length options to suit installation environments and requirements.
Environmental Suitability: Factor in considerations such as the jacket material (PVC, Riser, Plenum, Armored) to ensure compatibility with diverse environmental conditions.
Conclusion:
The MTP Fiber Optic Patch Cable and its Buying Guide present a comprehensive solution for high-density networking needs. By understanding the key features and utilizing the buying guide, one can make informed decisions in selecting the most suitable fiber optic patch cable for their specific network requirements.
11. Future Trendsand Developments in MPO/MTP Technology
Understanding Current and Future Requirements:
Recognizing both immediate and potential future needs in cable production before investing in MPO test equipment.
Costs and Challenges of Channel Count Upgrades:
Evaluating the expenses and opportunity costs involved in upgrading channel count capabilities within an existing system. Acknowledging limitations in upgradability and comparing upgrade costs to purchasing new equipment.
Assessing Equipment Compatibility:
Highlighting compatibility issues, such as power meters designed for specific fiber counts and their limitations in handling different configurations, like transitioning from 12-fiber to 16-fiber connectors.
Strategic Decision-making for Production Floors:
Weighing the advantages and disadvantages of opting for a higher initial investment in MPO test equipment. Understanding the potential hidden costs and limitations that might arise from insufficient investments.
Visual Aid and Future Planning:
Utilizing illustrations of various MTP/MPO connectors with different fiber counts (12, 16, 24, and 32 fibers) to aid in visualizing the diversity of connector types. Emphasizing the need for assessing expandability to future-proof equipment choices.
Pre-Purchase Evaluation of Expandability:
Stressing the importance of evaluating the potential for expandability; for instance, if the current demand is for 12 fibers, assessing whether future needs might extend to 24, 16, 32, or other configurations.
Categorizing the content in this manner provides a structured approach to understanding the considerations and decision-making processes involved in investing in MPO test equipment, ensuring adaptability and foresight in meeting evolving cable production requirements.
FAQs
FAQs
MPO/MTP cables offer high-density connectivity, allowing more efficient space use in data centers. They also facilitate quick and easy installations and migrations due to their plug-and-play design.
MPO/MTP connectors can have various configurations, but common ones include 8, 12, 24, or even 72 fibers in a single connector.
MPO/MTP connectors are typically factory-terminated to ensure accuracy and performance. But field termination is also an option and requires specialized skills and tools. Field termination is complex and involves multiple optical fibers’ precise alignment and polishing. Quality control is more challenging compared to pre-termination.
MPO/MTP connectors are not directly compatible with LC or SC connectors. However, hybrid cables with MPO/MTP connectors on one end and traditional connectors on the other end are available to facilitate connections between different types of equipment.
While MPO/MTP connectors are designed for multiple mating cycles, it’s generally recommended to minimize reusing connectors, especially in critical applications. Repeated mating and demating can lead to wear and affect performance. In many cases, it’s more practical to use new connectors for optimal performance.
Testing MPO/MTP cables requires specialized equipment designed for multi-fiber connectors. Proper testing involves verifying continuity, insertion loss, and return loss. Regular testing and inspection are essential for maintaining network performance and troubleshooting potential issues.
MPO/MTP cables can be used in conjunction with older fiber optic systems, but compatibility depends on various factors, including the specific configuration of the MPO/MTP connector and the requirements of the legacy system. Hybrid solutions with conversion modules may be employed to ensure compatibility with older connectors and systems.
Consider factors like fiber type, cable length, connector polish type (PC, UPC, APC), and application-specific requirements to select the suitable MPO patch cord for your needs.
The utilization of traditional optical fibers in data centers has posed challenges, notably in terms of space efficiency and the management complexity of wiring systems. However, the introduction of MTP/MPO fiber jumpers has significantly addressed these issues. These specialized cords have greatly enhanced the space utilization within data centers, thereby contributing to their widespread adoption in modern setups.